Architectural Grade Super Durable Polyester

View / Download PDF Data Sheet

A.S.D. Grade - Is our Architectural Grade Super Durable Polyester Powder Coatings. They are very UV and weather resistant coatings formulated to meet or exceed the AAMA 2604 requirements. The architectural coating specifier may find these coatings well suited for high traffic architectural aluminum components such as doors, railings, and storefronts as they demonstrate superior mechanical properties of impact and scratch resistance when compared to liquid coatings. This grade of coatings also utilizes the superior UV resistant, inorganic, and/or mix metal oxide pigments, These pigment categories are the most impervious to UV degredation and have been proven to retain their original color and resist fading

A.S.D. Grade Physical Properties and Tests

Specific Gravity: 1.4 to 1.8 g/cm3 varies by color
Cure Schedule, Peak Metal temperature: 15 to 25 minutes at 400 degrees F
  20 to 40 minutes at 380 degrees F
Film Thickness: 2.5 to 4.0 mils, with no measurement below 1.8 mils
Specular Gloss Values: 30 to 85 Using a 60 degree gloss meter per ASTM D 523
Dry Film hardness AAMA 2604-05, 7.3 Pass, no rupture of film
Film Adhesion: AAMA 2604-05, 7.4 7.4.1.1 Dry Adhesion Pass, no removal of film
7.4.1.2 Wet Adhesion Pass, no removal of film
7.4.1.3 Boiling Water Adhesion Pass, no removal of film
Impact Resistance: AAMA 2604-05, 7.5 Pass, no removal of film
Abrasion Resistance: AAMA 2604-05, 7.6 Pass, exceeding abrasion coefficient value 20 min.
Chemical Resistance: AAMA 2604-05, 7.7 7.7.1 Muriatic Acid Resistance Pass
7.7.2 Mortar Resistance Pass
7.7.3 Nitric Acid Resistance Pass
7.7.4 Detergent resistance Pass
7.7.5 Window Cleaner resistance Pass
Corrosion Resistance: AAMA 2604-05, 7.8 7.8.1 Humidity Resistance, 3,000 hrs Pass
7.8.2 Salt Spray Resistance, 3,000 hrs Pass
Weathering: AAMA 2604-05, 7.9 Atlas South Florida Pass

Metal Preparation and Pretreatment:

A multi stage cleaning and pretreatment system is required to prepare the substrate. A properly operating pretreat system will remove organic and inorganic surface soils, remove residual oxides, and apply a chemical conversion coating to which organic coatings will adhere. Pretreat chemical conversion solutions and rinses must utilize high purity water, and may be of chrome containing conversion, or non-chrome conversion chemistries. Applicator pretreat solutions and processes must comply with the chemical supplier’s procedures and guidelines. Frequent in-plant testing and control of pretreatment is required to insure satisfactory performance of the coating system.

Application:

A.S.D. Grade coatings are designed for application by electrostatic spray – manual or automatic. Reclaim is acceptable, provided there is no incident of cross-contamination. Reclaimed coatings which contain special effect micas should be evaluated for consistency. When applying A.S.D. Grade, some experimentation is typical with regard to gun kV settings and air velocities to maximize transfer efficiency and achieve a consistent coating thickness. Curing by means of gas fired convection oven with proper exhausting is the industry norm. Oven profiling is required to evaluate the cure process.

Precautions:

All dusts are respiratory irritants. The coating area must be properly ventilated. If skin contact occurs, wash with mild, soapy water. If eye contact occurs, flush with water immediately and secure medical attention. Dust clouds of any finely divided organic material can be ignited by electrical sparks or open flames. All equipment must be electrically grounded to preclude buildup of static electricity. Ensure adequate oven ventilation when curing this product. See MSDS for further precautions.

Storage Stability:

The maximum storage temperature for this coating is 80°F at 50% Relative Humidity. Under these conditions, a shelf life of 12 months is expected.

Disclaimer:

We urge you to consult with Crosslink and to perform your own tests to determine the suitability of this product for your particular purposes. The information contained herein is to the best of our knowledge, and is not intended to be exhaustive. It is intended to inform users of the general criteria regarding this coating. We have no control over either the quality or condition of the substrate, the processes of pretreat, application, or curing, or the many factors affecting the use, application or final installed environment of the coated product. We make no guarantee of results, and assume no liability for damages incurred by following these suggestions, or for misuse. We do not accept any liability whatsoever or howsoever arising from the performance of the product or for any loss or damage arising out of the use of the product. Any product liability shall be incurred in writing only. The information contained in this sheet is subject to modification from time to time due to experience and continuous product development.